TAHP-過氧化氫叔戊基--CAS.3425-61-4
公司: | 山東海京新材料有限公司 |
---|---|
聯(lián)系人: | 劉總 |
手機(jī): | 13220762561 |
電話: | 0536-8688945 |
地址: | 山東省濰坊市濱海區(qū)大家洼街道?;著S 都大廈1號樓601 |
留言咨詢 更多信息 | |
分享: |
![]() |
產(chǎn)品介紹
商品名稱:TAHP
中文名稱:過氧化氫叔戊基
化學(xué)名稱:特戊基過氧化氫
分子式:C5H12O2
分子量:104.1
理論活性氧含量:15.36%
CAS號:3425-61-4
主要分解產(chǎn)物:甲烷,叔戊醇。
指標(biāo)Safety indicators:
半衰期(純產(chǎn)品測得):
0.1小時(shí):202℃
1小時(shí):183℃
10時(shí):165℃
自加速分解溫度(SADT):80 ℃
報(bào)警溫度(Tem):75℃
控制溫度(Tc):--
貯存溫度(Tsmax):--/15 ℃
技術(shù)標(biāo)準(zhǔn):
純度:85%±1.0%
活性氧含量:10.92-11.18%
其它過氧化物:2% max
用途:
TAHP是一種常用的自由基反應(yīng)的引發(fā)劑,其特點(diǎn)是熱穩(wěn)定性好,易于控制,在50℃以下,其活性在三個(gè)月內(nèi)無明顯變化,且無須費(fèi)用較高的冷凍貯存,可用于乳液聚合、水相聚合、固化及接技聚合等領(lǐng)域,在許多方面的性能優(yōu)于過二硫酸鹽、異丙苯過氧化氫和過氧化苯甲酰。TAHP的分解產(chǎn)物主要為叔丁醇等,無腐蝕性,對設(shè)備要求不高。而其它引發(fā)劑多數(shù)都會(huì)形成酸性副產(chǎn)物。
TAHP同時(shí)也廣泛地應(yīng)用于苯乙烯和苯乙烯共聚體(如SAN、ABS等),丙烯酸和甲基丙烯酸、氯乙烯的聚合引發(fā)劑。
TAHP是一種重要的有機(jī)合成中間體。
包裝
標(biāo)準(zhǔn)包裝是凈重25公斤或180公斤的聚乙烯塑料桶,也可用IBC包裝,但要特別注意用IBC包裝時(shí)SADT為50℃,危急溫度為55℃。小包裝也可按用戶的要求的規(guī)格包裝。
TAHP為E類液體有機(jī)過氧化物,貨物分類:5.2,聯(lián)合國編號:3107,二類危險(xiǎn)貨物包裝.
注意事項(xiàng):
(1) 遠(yuǎn)離火種、明火和熱源。
(2) 避免接觸還原劑(如胺類)、酸、堿和重金屬化合物(如促進(jìn)劑、金屬皂等)
(3) 請參照本產(chǎn)品的數(shù)據(jù)表(MSDS)。
貯存條件:
保持包裝密閉并處于良好通風(fēng)狀態(tài)下,貯存溫度≤35℃,避免和還原劑如胺類、酸、堿、重金屬化合物(促進(jìn)劑及金屬皂),嚴(yán)禁在庫房內(nèi)分裝及取用。
貯存穩(wěn)定性:
按廠家提示的條件進(jìn)行保存,產(chǎn)品在六個(gè)月內(nèi)可保證出廠技術(shù)標(biāo)準(zhǔn)。
滅火:
小的火災(zāi)需用干粉或二氧化碳滅火器滅火,同時(shí)用大量水噴灑,防止再燃。大火需在安 全距離之外用大量水噴射。
Product name:TAHP
English name:Tert-amyhyl droperoxide
Chemical name: terpentyl hydrogen peroxide
Molecular formula:C5H12O2
Molecular weight: 104.1
Theoretical active oxygen content: 15.36%
CAS.:3425-61-4
Main decomposition products: methane, tert amyl alcohol.
Safety indicators:
Half life (measured on pure products):
0.1 hour: 202 ℃
1 hour: 183 ℃
10 hours: 165 ℃
Self accelerating decomposition temperature (SADT): 80 ℃
Alarm temperature (Tem): 75 ℃
Control temperature (Tc):--
Storage temperature (Tsmax): --/15 ℃
Technical standards:
Purity:85%±1.0%
Active oxygen content:10.92-11.18%
Other peroxides:2% max
Purpose:
TAHP is a commonly used initiator for free radical reaction. It is characterized by good thermal stability, safe use, and easy control. Its activity does not change significantly within three months at temperatures below 50 ℃, and there is no need for costly frozen storage. It can be used in lotion polymerization, aqueous polymerization, curing, grafting polymerization and other fields. Its performance is superior to that of persulfate, cumene hydroperoxide, and benzoyl peroxide in many aspects. The decomposition products of TAHP are mainly tert butanol , which are non corrosive and do not require high equipment requirements. Most other initiators will form acidic byproducts.
TAHP is also widely used as an initiator for the polymerization of styrene and styrene copolymers (such as SAN, ABS, etc.), acrylic acid, methacrylic acid, and vinyl chloride.
TAHP is a very important intermediate in organic synthesis.
packing:
The standard packaging is a polyethylene plastic bucket with a net weight of 25 kilograms or 180 kilograms, which can also be packaged in IBC. However, it is important to note that when using IBC packaging, the SADT is 50 ℃ and the critical temperature is 55 ℃. Small packaging can also be packaged according to user specifications.
TAHP is a Class E liquid organic peroxide, with a cargo classification of 5.2 and a United Nations number of 3107. It is a packaging for Class II dangerous goods
Safety precautions:
(1) Keep away from sparks, open flames, and heat sources.
(2) Avoid contact with reducing agents (such as amines), acids, bases, and heavy metal compounds (such as accelerators, metal soaps, etc.)(3) Please refer to the Safety Data Sheet (MSDS) of this product.
Storage conditions:
Keep the packaging sealed and in a well ventilated state, with a maximum storage temperature of 35 ℃. Avoid mixing with reducing agents such as amines, acids, alkalis, and heavy metal compounds (accelerators and metal soaps). It is strictly prohibited to pack or use in the warehouse.
Storage stability:
Store according to the manufacturer's instructions, and the product can meet the factory technical standards within six months.
Fire extinguishing:
Small fires need to be extinguished with dry powder or carbon dioxide fire extinguishers, and a large amount of water should be sprayed to prevent reignition. A large fire requires spraying a large amount of water from a safe distance.